 SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC
SY02-FEC
Date: January 7, 2003
*
INTRODUCTION
The SY02-FEC is a high frequency crystal-based PLL synchronizer designed as a module level subsystem for easy incorporation into telecommunication equipment SONET/SDH/ATM/DWDM. Supports FEC (forward error Correction) or OC-N Frequencies.
*
-
FEATURES
Low jitter output from intrinsically low jitter VCXO or VCSO; User Selected one or two input references up to 800MHz ( See Table on page 3) One high frequency LVPECL output with enable/disable function up to 800MHz (pre-select frequency value - upon order) Alarms status and VCXO monitor; The unit changes timing modes in response to external events; J-TAG service port for re-programming and servicing; 3.3V DC power supply Small dimensions: 0.8" x 1.00"
*
-
APPLICATIONS
ATM SDH PDH SONET DWDM FEC Other telecommunication equipment.
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC
A=622.08MHz
REF REF IN IN Q Q
ALARM
Lock Monitor
VCXO Monitor MUX, FPD, Counters & Logic LOOP FILTER
OUT
Input Freq. Sel B= 666.513MHz
VCXO
OUT
J-TAG PORT
SY02-FEC
E/D
Figure 1 - Block Diagram (***Components outside the dotted line are user supplied)
.
*
DESCRIPTION
The SY02-FEC is a High Frequency Phase Lock Loop has been designed as a module level subsystem for easy incorporation into telecommunication equipment. The module generates the high frequency (up to 800MHz) output from a low jitter VCXO (Crystal Based Oscillator) or VCSO (SAW based oscillators). The output can be disabled externally by setting OUTEN pin high. The SY02-FEC can be locked to a user defined input reference/s signal/s (from 1.024MHz to 800MHz...for options please see table ). Raltron's SY02-FEC device could be used as a frequency translator in PLL circuits or frequency re-generator device in cases where jitter cleaning and filtering is required. The module has a fast locking time and tolerates reference inputs with different duty cycles. The loop bandwidth is optimized in accordance with the VCXO used and required output performance. The ALARM output signals monitor the status of the phase lock loop and indicates LOLD (Loss of Lock Detect). If the reference REF IN is absent, the SY02-FEC will automatically switch to free run mode and LOLD will show "0" logic level. The SMD package dimensions are 0.80"x1.00" inch and powered by a supply of 3.3V.
ALARM STATES
LOL D 0 1 ALARM Module in Free-run Module locked
Input Reference Control select
CNT 0 1 Selected Option Regenerated 622.08MHz into 622.08MHz Translates 666.5143MHz into 622.08MHz
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC
*
PIN DESCRIPTION
Name Description
Signal Technology Min Vcc-1.680 Vcc-1.680 0 VL Typ Vcc-1.620 Vcc-1.620 0.15 Max Vcc-1.560 Vcc-1.560 0.3 VH/ DC Voltage Min Typ Vcc-1.085 Vcc-1.025 Vcc-1.085 2.97 Vcc-1.025 3.3 Max Vcc-0.885 Vcc-0.885 3.465
1 2 3 4 6 7 8 9 10 11 12 13 14 15 16
Ref In Ref In LOL MNTR N/C GND Enable/Disable OUT OUT N/C CNT N/C N/C GND Vcc
Input Reference Signal Input Reference Complimentary signal Lock Detect Alarm out - High when locked; Low when unlocked VCXO Monitor out- DC control voltage offset indicator (when locked shall be within); 0.3 enables the output, active high or floating Disables the output, active low Oscillator Output -> Output of the module Oscillator Complementary Output -> Output of the module No Connect Frequency Select; Low-Primary Frequency; High Secondary Frequency No Connect No Connect Ground Positive supply voltage
LV/PECL LV/PECL DC DC
0.3--------0 --------0.15 ------0.3 ----------2.97 ----------3.3 ----------3.465
--------DC
LV/PECL LV/PECL ----DC ------------DC - 3.3V
Vcc-1.680 Vcc-1.680 ----0 -----------------
Vcc-1.620 Vcc-1.620 ----0.15 -----------------
Vcc-1.560 Vcc-1.560 ---0.3 -------------
Vcc-1.085 Vcc-1.085 -----2.97 ---------------2.97
Vcc-1.025 Vcc-1.025 -----3.3 ---------------3.3
Vcc-0.885 Vcc-0.885 -----3.465 ---------------3.465
*
ORDERING INFORMATION
o Input/Output Frequencies available; Frequency 77.7600MHz 78.125MHz 78.6432MHz 82.9440MHz 92.6000MHz 100.000MHz 112.000MHz 114.000MHz 125.000MHz 133.000MHz 139.264MHz 155.520MHz 156.250MHz 161.1328MHz 166.6286MHz 167.3316MHz Suffix O3 B3 B4 B5 U3 B6 B7 B8 G2 G4 E6 O4 G6 B9 B10 C1 Frequency 168.0407MHz 175.0000MHz 178.9440MHz 184.3200MHz 311.0400MHz 622.0800MHz 625.000MHz 644.5312MHz 666.5143MHz 669.1281MHz 669.3266MHz 690.5692MHz 710.9486MHz 719.7344MHz 777.6000MHz Suffix C2 C3 C4 C5 O6 O7 C8 C9 C10 F1 F2 F3 F4 F5 F6
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC
P/N System SY02-FEC - IP - IS-OUS-T
See above Chart If not listed Place NL and state the Freq.) See above chart (If not listed place NL and state the Freq. - must be higher in value than the primary Input reference) If second Freq. Not applied place NA See above Chart If not listed Place NL and state the Freq.) Supply Voltage; 4 - 3.3V Operating Temperature Range; C - 0C to 70C I - -40C to +85C *
SPECIFICATION
Mechanical Power Environment Internal Oscillators Number of Reference Inputs Input reference frequency Signal Level Number of Outputs Output 1 Output 1 Signal Level Duty Cycle Tracking/Capture Range Jitter generation 1.000" x 0.800"x0.235" 3.3VDC +/-5%, <200mA Operating Temperature Humidity VCXO or VCSO 2 Per selected table on page 3 LVPECL 1 Per selected table on page 3 LVPECL (W/ Complimentary option) 50+/-10% 50ppm APR min <0.001UI RMS <0.001UI RMS <0.0001 UI RMS <0.0001 UI RMS -40dB -10dB 2 s, 10 Hz (0.05 UI @ 8KHz) SMT Module FR4 16 pins dual-in-line Regulated 0C to 70C or -40C to +85C 5% to 95% non-condensing Depends on the frequency (other input frequencies available) Voh; 2.272V min ; Vol; 1.68Vmax other frequency contact Raltron Voh; 2.272V min ; Vol; 1.68Vmax 50%+/-5% available upon request HPF 30Hz HPF 500Hz HPF 12KHz HPF 100KHz Fj=10Hz~1KHz Fj=1KHz~10MHz
General Specifications
Input Signals
Output Signals
Signal Quality Performance
Jitter attenuation Jitter tolerance
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC * REFLOW PROFILE
250 200 150 XY (Scatter) 1 100 50 0 0 1 2 3 4 5 6 7 8
*
OUTLINE DRAWING
.040 (1.02) .250 MAX. (6.35 MAX.) .150 (3.81)
SIDE VIEW
.700 (17.78) .100 TYP. (2.54) 9 10 11 12 13 14 15 16 .055 (1.4) .050 (1.27)
1.000 (25.4)
MARKING AREA
.800 (20.32)
87
6
43
21
DENOTES PIN 1.
TOP VIEW
BOTTOM VIEW
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th


▲Up To Search▲   

 
Price & Availability of SY02-FEC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X